Search

Title Document Number
Sector Years
TC ICS

Catalogs

Preparation of documents used in electrotechnology-Part 2: function-orientaded diagrams

Provides rules for function oriented diagrams. Coverage includes: location reference systems; representation of supply circuits; representation of combined electrical and non electrical circuits; representation of binary logic circuits; terminals connected to internal branches; overview diagrams for control systems for non electrical processes; contents of a function diagram; contents of a circuit diagram; symbols with a large number of terminals.


Preparation of documents used in electrotechnology- Part 3: Connection diagrams, tables and lists

This standard contains definitions and general information applicable to most of the commonly used Electrical and Electronics Diagrams. It also includes detailed recommendations on preferred practices for use in the preparation of Electrical and Electronics Diagrams. The recommended practices covered by this standard are ground rules designed to eliminate divergent Electrical and Electronics Diagram drafting techniques. The illustrations shown represent good drafting practices. They are not intended as engineering design guides


Preparation of documents used in electrotechnology- Part 4: Location and installation documents

Provides rules for location and installation documents mainly used for installation work. Covers different systems and objects such as arrangements or installation drawings for site, buildings and equipment, installation drawings or diagrams for site or buildings and drawings for location on or in components.


Electromechanical contactors for household and similar purposes

This International Standard applies to electromechanical air break contactors for household and similar purposes provided with main contacts intended to be connected to circuits the rated voltage of which does not exceed 440 V a.c. with rated operational currents less than or equal to 63 A for utilization category AC-7a and 32 A for utilization category AC-7b, and rated conditional short-circuit current less than or equal to 6 kA. The contactors dealt with in this standard are not normally designed to interrupt short-circuit currents. Therefore, suitable short-circuit protection (see 9.3.4) shall form part of the installation. This standard does not apply to: contactors complying with IEC 60947-4-1; semiconductor contactors; contactors designed for special applications; auxiliary contacts of contactors. These are dealt with in IEC 60947-5-1. This standard states: 1) The characteristics of contactors. 2) The conditions with which contactors shall comply with reference to: a) their operation and behaviour; b) their dielectric properties; c) the degrees of protection provided by their enclosures, where applicable; d) their construction; e) their electromagnetic compatibility characteristics. 3) The tests intended for confirming that these conditions have been met, and the methods to be adopted for these tests. 4) The test sequences and the number of samples to be submitted for certification purpose. 5) The information to be given with contactors or in the manufacturer’s literature


Thermal insulation for building equipment and industrial installations - Calculation rules

This International Standard gives rules for the calculation of heat transfer properties of building equipment and industrial installation, predominantly under steady-state conditions, assuming one-dimensional heat flow only.


Connecting devices for low voltage circuits for household and similar purposes- Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units.

This standard applies to connecting devices with screw-type clamping units primarily suitable for connecting unprepared conductors. This Part 2-1 is intended to be used in conjunction with IEC 60998-1. It was established on the basis of the second edition (2002) of that standard. This second edition cancels and replaces the first edition published in 1990 and constitutes a technical revision


Connecting devices for low voltage circuits for household and similar purposes- Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units.

This standard applies to connecting devices with screwless-type clamping units primarily suitable for connecting unprepared conductors. This Part 2-1 is intended to be used in conjunction with IEC 60998-1. It was established on the basis of the second edition (2002) of that standard. This second edition cancels and replaces the first edition published in 1991 and constitutes a technical revision.


Connecting devices for low voltage circuits for household and similar purposes- Part 2-3: Particular requirements for connecting devices as separate entities with insulation piercing clamping units.

This standard applies to connecting devices with insulation piercing clamping units primarily suitable for connecting insulated unprepared conductors. In the connecting operation the insulation of the conductor is pierced, bored through, cut through, removed, displaced or made ineffective in some other manner at the point or points of contact. This Part 2-1 is intended to be used in conjunction with IEC 60998-1. It was established on the basis of the second edition (2002) of that standard. This second edition cancels and replaces the first edition published in 1991 and constitutes a technical revision. The contents of the corrigendum of November 2006 have been included in this copy.


Connecting devices for low voltage circuits for household and similar purposes- Part 2-4: Particular requirements for twist-on connecting devices.

This International Standard applies to twist-on connecting devices for connecting two or more unprepared rigid and/or flexible copper conductors having a cross-sectional area of 0,5 mm2 up to and including 16 mm2 and complying with IEC 60228, the total cross-sectional area of the connected conductors not exceeding 35 mm2. It covers low voltage circuits up to 1 000 V a.c. and 1 500 V d.c. where electrical energy is utilized for household and similar purposes


Low-voltage switchgear and controlgear- Part 4 : Contactors and motor starters -Section 1:Electromechanical contactors and motor-starters - Amendment 1

IEC 60947-4-1:2018 RLV contains both the official IEC International Standard and its Redline version. The Redline version is not an official document, it is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 60947-4-1:2018 is applicable to the following equipment: - electromechanical contactors and starters including motor protective switching device (MPSD); - actuators of contactor relays; - contacts dedicated exclusively to the coil circuit of this contactor or this contactor relay; - dedicated accessories (e.g. dedicated wiring, dedicated latch accessory); intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. This fourth edition cancels and replaces the third edition published in 2009 and its Amendment 1:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Scope structure and exclusions - Editorial correction of notes and hanging paragraphs - Reference to IEC 62683-1 - Motor protective switching device (MPSD) with its requirements - Safety aspects related to: - General aspects; - Limited energy circuits; - Electronic circuits; - Assessment procedure for electromechanical overload protection used in safety -applications (new Annex L) - Introduction of provisions covering the impact of higher locked rotor current to achieve high efficiency class - Mention of dedicated wiring accessories - Pickup power measurement - Alignment to IEC 60947-1:2007, IEC 60947-1:2007/AMD1:2010, and IEC 60947‑1:2007/AMD2:2014 - Direct current requirements for covering photovoltaic application (new Annex M) - Load monitoring indicators (new Annex O) - Short-circuit breaking tests of MPSD (new Annex P) - Co-ordination under short-circuit conditions between a MPSD and another short-circuit protective device associated in the same circuit (new Annex Q).


Low-voltage switchgear and controlgear- Part 5: Control circuit devices and switching elements - Section 1: Electromechanical control circuit devices - Amendment 1

IEC 60947-5-1:2016 RLV contains both the official IEC International Standard and its Redline version. The Redline version is not an official document, it is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 60947-5-1:2016 applies to control circuit devices and switching elements intended for controlling, signalling, interlocking, etc., of switchgear and controlgear. It applies to control circuit devices having a rated voltage not exceeding 1 000 V a.c. (at a frequency not exceeding 1 000 Hz) or 600 V d.c. This fourth edition cancels and replaces the third edition published in 2003 and its Amendment 1:2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) update of normative references; b) update and restructuration of subclauses in 7.1; c) addition of material requiremen


Low-voltage switchgear and controlgear- Part 6: Multiple function equipment - Section 1: Automatic transfer switching equipment - Amendment 1

IEC 60947-6-1:2005+A1:2013 applies to transfer switching equipment (TSE) to be used in power systems with interruption of the supply to the load during transfer, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c. This consolidated version consists of the second edition (2005) and its amendment 1 (2013). Therefore, no need to order amendment in addition to this publication. This publication is to be read in conjunction with IEC 60947-1:2007.


Low-voltage switchgear and controlgear- Part 3: Switches,disconnectors,switch-disconnectors and fuse-combination units

IEC 60947-3:2008+A1:2012+A2:2015 applies to switches, disconnectors, switch-disconnectors and fuse-combination units to be used in distribution circuits and motor circuits of which the rated voltage does not exceed 1 000 V a.c. or 1 500 V d.c. The manufacturer shall specify the type, ratings and characteristics according to the relevant standard of any incorporated fuses. The technical content is therefore identical to the base edition and its amendment and has been prepared for user convenience. A vertical line in the margin shows where the base publication has been modified by amendment 1. Additions and deletions are displayed in red, with deletions being struck through. The contents of the corrigenda of September 2012 and of November 2013 have been included in this copy. This consolidated version consists of the third edition (2008), its amendment 1 (2012) and its amendment 2 (2015). Therefore, no need to order amendments in addition to this publication. This publication is to be read in conjunction with IEC 60947-1:2011.


Canned Pears

تهدف هذه المواصفة القياسية إلى تحديد المتطلبات والشروط الواجب توافرها في الأجاص المعلّب


Canned Pineapple

تهدف هذه المواصفة القياسية إلى تحديد المتطلبات والشروط الواجب توافرها في الأناناس المعلّب


Carrots

تهدف هذه المواصفة القياسية الى تحديد الشروط والمتطلبات الواجب توافرها في الجزر الموضب والمعد للتسويق طازجاً. لا تطبق هذه المواصفة القياسية على الجزر المخصص للتصنيع.


Fresh Figs

تهدف هذه المواصفة القياسية إلى تحديد الشروط والمتطلبات الواجب توافرها في التين الموضب والمعد للتسويق طازجاً. لا تطبق هذه المواصفة القياسية على التين المخصص للتصنيع.


Green Beans

تهدف هذه المواصفة القياسية إلى تحديد الشروط والمتطلبات الواجب توافرها في الفاصولياء الخضراء المعدة للتسويق في حالة طازجة، وذلك عند مرحلة التوزيع بعد التهيئة والتوضيب. لا تطبق هذه المواصفة القياسية على الفاصولياء الخضراء المخصصة للتفصيص أو للتصنيع


Canned Fruit Cocktail

تهدف هذه المواصفة القياسية إلى تحديد المتطلبات والشروط الواجب توافرها في كوكتيل الفواكه المعلّبة المعد للاستهلاك المباشر


Dried Apricots

تهدف هذه المواصفة القياسية إلى تحديد المتطلبات والشروط الواجب توافرها في المشمش المجفف المعالج بطريقة ملائمة والمعد للاستهلاك المباشر. كما تشمل المشمش المجفف المعبأ في أوعية كبيرة مناسبة بغرض إعادة تعبئته للبيع المباشر إلى المستهلك. لا تطبق هذه المواصفة القياسية على منتج القمر الدين


Mango Nectar

تهدف هذه المواصفة القياسية إلى تحديد المتطلبات والشروط الواجب توافرها في نكتار المانجو المحفوظ فقط بالطرق الفزيقية والمعد للاستهلاك المباشر


Citrus Fruit Nectars

تهدف هذه المواصفة القياسية إلى تحديد المتطلبات والشروط الواجب توافرها في النكتار المعبأ والمعد للاستهلاك المباشر، المحضر من أصناف الحمضيات التالية: - البرتقال (Citrus sinensis L. Osbeck) - الأفندي والتنجرين الخ… (Citrus reticulata) - الجريب فروت أو البوميلو (Citrus paradisi Macfayden


Mixed Fruit Nectars

تهدف هذه المواصفة القياسية إلى تحديد المتطلبات والشروط الواجب توافرها في نكتار الفواكه المشكلة المعبأ والمعد للاستهلاك المباشر، المحفوظ فقط بالطرق الفزيقية.


Apricot, Peach and Pear Nectars

تهدف هذه المواصفة القياسية إلى تحديد المتطلبات والشروط الواجب توافرها في نكتار المشمش والدراق والأجاص المعبأ والمعد للاستهلاك المباشر، المحفوظ فقط بالطرق الفزيقية.


Dried Grapes

تهدف هذه المواصفة القياسية إلى تحديد المتطلبات والشروط الواجب توافرها في العنب المجفف (الزبيب) المعالج بطريقة ملائمة والمعد للاستهلاك المباشر، والعنب المجفف المعبأ في أوعية كبيرة مناسبة بغرض إعادة تعبئته للبيع المباشر إلى المستهلك. لا تطبق هذه المواصفة القياسية على ثمار الكرمة المجففة المشابهة والمعروفة باسم الكشمش المجفف.


General Principles of Food Hygiene

تهدف هذه المواصفة القياسية الى تحديد الشروط الصحية الضرورية لإنتاج غذاء سليم وصالح للاستهلاك، وذلك خلال جميع مراحل السلسلة الغذائية، أي بدءاً من عملية الإنتاج الأولي حتى الوصول إلى المستهلك النهائي. كما تشكل هذه المواصفة قاعدة أساسية لأنظمة أخرى أكثر تحديداً، تطبق في قطاعات محددة. يجب أن توضع هذه الأنظمة والتوجيهات المحددة بالتلازم مع هذه المواصفة القياسية ومع نظام تحليل مصادر الخطر ونقاط المراقبة الحرجة (HACCP) والتوجيهات الخاصة بتطبيقه


Gasoil for gas turbines for the production of electric power

تحدد هذه المواصفة القياسية الشروط الواجب توافرها في غاز أويل الملائم كوقود لحراقات تربينات الغاز لتوليد الطاقة الكهربائية والذي قد يحتاج إلى تسخين أولي ولا تشمل هذه المواصفة القياسية خصائص الوقود المستعملة في تربينات الغاز للطائرات.


Residual fuel oil for combaustion in steam boilers for the generation of power

تحدد هذه المواصفة القياسية الشروط الواجب توافرها في زيت الوقود المتخلف الملائم للحرق في المراجل البخارية لتوليد الطاقة الحرارية والكهربائية وهو يحتاج إلى تسخين أولي


Special Dietary Foods with Low Sodium Content (Including Salt Substitutes)

تهدف هذه المواصفة القياسية الى تحديد المتطلبات والخصائص الواجب توافرها في الأغذية التي تم وصفها بشكل مباشر أو غير مباشر أو بشكل ضمني بأنها أغذية ذات استعمالات تغذوية خاصة نتيجة احتوائها على كمية قليلة من الصوديوم. كما تطبق على بدائل الملح التي تحتوي على كمية قليلة من الصوديوم. تحدد هذه المواصفة القياسية الخصائص المتعلقة فقط بمحتوى الصوديوم في الأغذية ذات الاستعمالات التغذوية الخاصة وبدائل الملح، ولا تتضمن الخصائص الأخرى المتعلقة بتكوين هذه الأغذية بما فيها مضافات الغذاء، إلا في حال بدائل الملح


Adult Diapers

تحدد هذه المواصفة القياسية الاشتراطات الواجب توفرها في الحفائض الجاهزة للبالغين للاستعمال لمرة واحدة


Female sanitary napkins

تحدد هذه المواصفة القياسية الاشتراطات الواجب توفرها في الفوط الصحية النسائية للاستعمال لمرة واحدة.


Whey Powders

تحدد هذه المواصفة القياسية المتطلبات والخصائص الواجب توافرها في مصل الحليب المجفف. كما تحدد طرق أخذ العينات والاختبار وشروط التعبئة والتخزين والنقل. ولا تطبق هذه المواصفة القياسية على المساحيق المحضرة من المصل غير القلوي وغير الحمضي والمصل الخالي من المعادن.


Edible Casein Products

تحدد هذه المواصفة القياسية المتطلبات والخصائص الواجب توافرها في الكازيين الغذائي ومنتجاته الصالحة للأكل والمعدة للاستهلاك المباشر، أو التي تحتاج الى معالجات لاحقة


Kitchen sinks - connecting dimensions

تهدف هذه المواصفة القياسية الى تحديد المتطلبات والشروط الواجب توافرها في كعوب الارضي شوكي(الخرشوف)المعلبة المعدة للاستهلاك المباشر


Jelly Powder

تحدد هذه المواصفة القياسية المتطلبات والخصائص الواجب توافرها في مسحوق الجيلي المعبأ


Preservatives Permitted in Food Products

تحدد هذه المواصفة القياسية المواد الحافظة المسموح بإضافتها للمنتجات الغذائية.


Emulsifiers, Stabilizers and Thickeners Permitted in Food Products

تحدد هذه المواصفة القياسية المواد المستحلبة والمثبتة والمثخنة المسموح بإضافتها للمنتجات الغذائية.


Antioxidants Permitted in Food Products

تحدد هذه المواصفة القياسية المواد المضادة للأكسدة المسموح بإضافتها للمنتجات الغذائية.


Hazard Analysis and Critical Control Point (HACCP) System and Guidelines for its Application

La première section du présent document définit les principes du Système d’analyse des risques – points critiques pour leur maîtrise (HACCP), adopté par la Commission du Codex Alimentarius. La deuxième partie donne des orientations générales concernant l’application de ce système, tout en reconnaissant que les détails de sa mise en oeuvre peuvent varier selon les circonstances.2


Potato Chips

تحدد هذه المواصفة القياسية المتطلبات الواجب توافرها في رقائق البطاطا، المحضرة من درنات البطاطا، المقلية والمعبأة والمعدة للاستهلاك المباشر. كما تشمل طرق أخذ العينات والاختبار وشروط التعبئة والتخزين والنقل.


Infant and Children Dietary Foods for Special Medical Purposes

تحدد هذه المواصفة القياسية المتطلبات والخصائص الواجب توافرها في أغذية الرضّع والأطفال المعدة لحالات طبية خاصة.


Custard Powder

تحدد هذه المواصفة القياسية المتطلبات والخصائص الواجب توافرها في مسحوق الكاسترد المعبأ.


Corn Flakes

تحدد هذه المواصفة القياسية المتطلبات الواجب توافرها في رقائق الذرة الجاهزة للأكل


Peanut Butter

تحدد هذه المواصفة القياسية المتطلبات والخصائص الواجب توافرها في زبدة الفول السوداني. كما تشمل طرق أخذ العينات والاختبار وشروط التعبئة والنقل والتخزين


Shortening

تحدد هذه المواصفة القياسية المتطلبات والخصائص الواجب توافرها في الشورتنينغ. كما تشمل طرق أخذ العينات والاختبار وشروط التعبئة والتخزين والنقل.


Luncheon Meat

تحدد هذه المواصفة القياسية المتطلبات والخصائص الواجب توافرها في لحم اللانشون المعلب والمعد للإستهلاك البشري. كما تشمل طرق أخذ العينات والاختبار وشروط التعبئة والتخزين والنقل.


Corned Beef

تحدد هذه المواصفة القياسية المتطلبات والخصائص الواجب توافرها في الـ"كورند بيف". كما تشمل طرق أخذ العينات والاختبار وشروط التعبئة والتخزين والنقل. ولا تطبق هذه المواصفة القياسية على المنتجات التي لا تطابق في تركيبها المتطلبات والخصائص الواردة في هذه المواصفة


Chopped Meat

تحدد هذه المواصفة القياسية المتطلبات والخصائص الواجب توافرها في لحم تشوبد. كما تشمل هذه المواصفة القياسية طرق أخذ العينات والاختبار وشروط التعبئة والتخزين والنقل.


Bouillons and consommés

تحدد هذه المواصفة القياسية المتطلبات والخصائص الواجب توافرها في مرق و"كونسوميه" اللحوم والمنتجات المشابهة المسماة بتسميات مماثلة والمعدة للاستهلاك المباشر بأشكالها المختلفة الجاهزة للأكل أو المجففة أو المكثفة أو المجمدة أو المركزة.


Atomizing Oil Burners : Connecting Dimensions Between Burners and Heat Generatorss

appareil de chauffage brûleur à mazout brûleur pulvérisation générateur d'air chaud classification liaison mécanique fixation dimension tolérance de dimension.